How to Read a Filter Housing Drawing Before You Approve It
Share
A filter housing drawing is approved in nine checks, in this order: the title block and revision, the overall dimensions, the ports, the nozzle orientation and projections, the closure, the element seat, the legs or bracket, the material and finish callouts, and the notes. The drawing is the contract: what is on it is what gets welded, so a port written as "1 in BSP" with no thread form is a problem you approve into existence. Ten minutes with the sheet saves a housing that does not bolt to your pipe.
- Title block first: drawing number, revision, units, scale, general tolerance, standard drawn to.
- Then the views: elevation, plan, sections and details; orientation angles live on the plan view.
- Then the nozzle schedule: every port by mark, size, type or rating, elevation, angle, projection and service.
- Then the build: closure, seat, legs, material per part, finish per surface, drain and vent.
- Last the notes: what is not drawn but is still binding.
This is the drawing chapter of our stainless steel filter housing buyer's guide. The quote checklist covers what to send before the drawing exists; this article covers what to check once it arrives.
What is a filter housing drawing?
For a standard housing it is one sheet: a general arrangement (GA) drawing with the vessel in elevation, the ports in plan, the overall dimensions and a small parts list; a custom bag or multi-cartridge vessel adds one or two detail sheets. A training guide for vessel fabricators describes the GA as the "master orthographic layout" of a vessel, showing envelope dimensions, nozzle locations, supports, design parameters and a bill of materials (Open Exam Prep, vessel GA drawings). A filter housing is a small pressure vessel, so the same conventions apply.
Where do you start on a filter housing drawing?
At the title block, bottom right. It carries the part name, the drawing number, the revision letter or number, the scale, the units, the general tolerance that applies to every dimension not toleranced individually, and the standard the drawing follows (Accu, how to read technical drawings). Confirm three things first: the units, that the revision is the latest you were sent, and that the general tolerance is one you can live with. Craftsmen Industries puts the revision rule bluntly: "Always confirm you are working from the latest revision before cutting material" (Craftsmen Industries, reading fabrication drawings). The same applies before approving.
How do you read the views?
A housing drawing uses three or four views. The elevation is the side profile: overall height, the height of each port centerline above the base, leg height, and the headroom above the lid. The plan looks down the vessel axis and shows where each nozzle points. Vessel drawings give that as an angle from a reference: an inlet at 0 degrees and an outlet at 180 degrees is a straight-through housing, an outlet at 90 degrees a right-angle one. A section, marked A-A, cuts the shell open to show the basket seat, the tube sheet or the cartridge cups. Details, marked with a letter, blow up a weld prep, a lifting lug or a bolt pattern. Read the geometry before the numbers: which way the liquid goes and how the lid comes off.
How do you check the ports?
On the nozzle schedule, the table that lists every connection. Vessel drawings give each nozzle a mark, size, rating, elevation, orientation angle, projection and service (Open Exam Prep); a housing drawing has the same columns, smaller. Check each line against your pipework:
- Threaded ports: the thread form must be written. "1 in BSP" is not a specification, because BSP covers both the parallel G thread and the tapered R thread, and they do not seal against each other. Our BSP ports are G (BSPP) parallel thread, not NPT and not PT or R tapered thread; see the BSP housing page and NPT vs BSP.
- Flanged ports: the standard and the rating together, ASME B16.5 Class 150 or EN 1092-1 PN16, plus the facing, raised face or flat face. A flange that matches on size but not on standard does not bolt up.
- Sanitary ports: the ferrule outside diameter, since Tri-Clamp ports are specified by the clamp size, not the bore.
- Projection: the distance from the vessel centerline "to the finished mating gasket face," the figure your pipe fitter needs.
- Service: which port is inlet, outlet, drain, vent and gauge.
What about the closure, the seat and the legs?
The closure should be named in the parts list: threaded sump, clamp closure, swing bolt or bolted cover. A clamp closure, a band clamp around lid and shell, is not Tri-Clamp ports; one is in the parts list, the other is in the nozzle schedule. The section view shows the seat: for a bag housing, the basket and the ring style it takes, steel ring or plastic snap ring; for a cartridge housing, the cup or knife edge and the end style, double open end or 222 or 226 O-ring, and the number of elements. If the section does not show how the element seals, ask. Legs or a bracket appear in elevation with a height and in plan with a bolt pattern; check both against your floor. On a top-opening housing, look for the headroom dimension above the lid: the element has to come out, and top entry and side entry housings need different clearances.
How are material and finish shown?
In two places. The parts list gives a material per item: shell and heads, nozzles, flanges, basket or tube sheet, legs, gasket, drain valve, fasteners. Read the grade line by line. A shell listed as SUS316 describes the housing body only; the gasket, fasteners and drain valve each have their own line, and the drain valve we fit as standard is not stainless steel. The body grade can be checked on the finished housing with a PMI reading, which this article explains; ask for it in the notes.
Finish is shown as a general finish in the title block, the default for every unmarked surface, with surface symbols on the views for anything different (Accu). On a housing that means an inside and an outside finish, named separately: 2B mill, brushed, mirror polished or electropolished, with an Ra value if your site needs one. Surface symbols follow ISO 1302 and weld symbols AWS A2.4 (Craftsmen Industries). You do not need to read weld symbols fluently; you need to see that the shell, nozzle and seat welds are marked continuous and the inside finish after welding is stated.
Filter housing drawing checklist
| Item | Where on the drawing | What to check | Common miss |
|---|---|---|---|
| Revision and units | Title block | Latest revision; mm or inches; general tolerance | Approving an old revision |
| Envelope | Elevation and plan | Overall height, diameter, footprint, headroom to open | No headroom dimension |
| Port size and type | Nozzle schedule | NPT or G (BSPP) written in full; flange standard, class and facing; ferrule size | "BSP" with no G or R |
| Port position | Plan and elevation | Angle between inlet and outlet; centerline heights; projection to gasket face | Outlet on the wrong side |
| Closure | Parts list, elevation | Threaded, clamp closure, swing bolt or bolted, named | "Clamp" read as Tri-Clamp ports |
| Element seat | Section view | Bag ring style or cartridge end style; element count | Seat for the wrong ring |
| Legs or bracket | Elevation and plan | Height, bolt pattern, adjustable or fixed | Legs too short for the drain |
| Material | Parts list | Grade per part; body grade vs valve, gasket, fasteners | Assuming one grade for all parts |
| Finish and welds | Title block, surface symbols, weld symbols | Inside and outside finish named; Ra if required; continuous welds | "Polished" with no surface named |
| Drain, vent, gauge | Nozzle schedule | Present, sized, positioned low and high | No vent on a tall vessel |
| Notes | Note block | Documents to supply; PMI reading requested; do not scale | Unread |
What is on the drawing that you should not fill in yourself?
Design pressure and temperature. If the drawing carries them, that is the manufacturer's statement for that model and the figure to compare against your line. If it does not, do not fill the blank from a catalog or a similar vessel; ask for it in writing on the quotation. The same goes for documents: if your site needs a design code, a material certificate or a pressure test record, it belongs in the notes, and the quotation should say what can be supplied. And never measure the drawing with a ruler to recover a missing dimension; the "do not scale" note exists because prints are rarely to scale.
What happens after you approve it?
The drawing becomes the build record: the housing is fabricated to it and the finished dimensions are checked against it before shipment, so if a dimension matters to you, say so at approval. We work from customer drawings or produce our own for approval, deliver to the dimensions on the approved drawing, and the minimum order for a custom vessel is one piece. Standard bag filter housings and multi-cartridge housings are ordered from the catalog; anything else starts on the custom filter housing page.
FAQ
Do I need to send my own filter housing drawing?
No. Send the liquid, flow, ports, layout and element, and a drawing comes back for approval. If you have one already, send it and it is quoted to it.
The drawing says "1 in BSP". Is that enough?
No. Ask for it to be written as G (BSPP) parallel thread or R tapered thread. Ours are G (BSPP), sealed on a washer at the face; if your fittings are R or NPT, say so before approval.
What is the difference between a GA drawing and a detail drawing?
The GA shows the whole housing, its envelope, ports and parts list, and is what you approve. Detail drawings show single parts or joints, such as a basket seat or a nozzle weld, and are mostly for the shop.
Can I change something after I approve the drawing?
Before fabrication starts, yes, as a new revision you approve again. After the shell is cut, a moved nozzle is rework, so check the nine points before signing.
Does "SUS316" on the drawing mean every part is 316?
No. It means the part on that line, usually the shell and heads. Gaskets, fasteners and the drain valve have their own lines and their own materials, and the drain valve we fit as standard is not stainless steel.
Have a drawing to check or one to be drawn?
Send yours and we quote to it, or send the duty and we draw it for your approval. Either way the housing is delivered to the approved drawing, with the body grade verifiable by PMI. Start at custom bag and multi-cartridge filter housings or request a quote.